Ground loop can cause considerable currents to flow on all cables on the loop. It is not uncommon to have a voltage of 1V RMS between the earth connections of power outlets that are wired separately back to the switchboard. This small voltage, with a total resistance of perhaps 0.2-0.5 Ohm, will cause a loop current of 2 to 5 Amps, all of which flows in the shield of the interconnect. This is sufficient to cause a voltage difference across the interconnect, which the amplifier cannot differentiate from the wanted signal. An earth loop will typically inject either a 50Hz or 60Hz hum into the signal.

You might have seen the following kind of device marketed for ground loop problem solving for USA markets:

HumX

The product page boasts with the following features: The Hum X Exterminator removes unwanted voltage and current in the ground line that cause ground loop hum. This noise reduction adapter simultaneously maintains a solid, safe ground. You no longer have to run your audio signal through filtering that results in loss of volume, tone, or both. Some devices simply remove or float the ground, which is never safe! Hum X removes the ground loop while leaving the ground and your signal intact. Easy to use and completely effective!

The question what comes to my mind when I saw this is how this thing works. Harmony Central Ebtech Hum-X Review gives some interesting details how this device is expected to work:

After briefly analyzing the input to output ground connections I found this to be very similar to a galvanic isolator that is widely used in the boating communities for ship to shore power connections. It appears that there are two diodes and a 1Kohm impedance that are connected in parallel from input ground to output ground. The parallel diodes are configured back to back so that there is a 0.7volt drop in each direction. Since I could not look inside the unit the diodes are an assumption on my part? they may have used transistors configured as diodes. The potential safety hazard here, is that one or both of these diodes could fail open leaving the user with no safety ground.

Non-isolating isolator article gives information how those boat isolators work: When a boat plugs into shorepower, the shorepower cord will often make an electrical connection between the underwater metals on all the boats that are plugged in, creating a risk of galvanic corrosion. A galvanic isolator is designed to prevent this by blocking DC currents with voltages that reach as much as -1.2 volts DC. This is achieved by installing two sets of devices known as ‘diodes’, with one set installed in the opposite direction to the other. There are two types of galvanic isolator, one with a device known as a ‘capacitor’ wired around the diodes, and one without. Without a capacitor, if there is AC leakage on the shorepower ground circuit that has a voltage above 1.2 volts AC, this AC leakage will ‘bias’ the diodes into a conductive state.

Narrowboat AC Electrical systems article give the following application example for boat galvanic isolator use:

boat_isolator

When the isolator is used for galvanic corrosion protection we want to block the DC and let the AC pass though, so the quite large capacitor in parallel with the diodes is a good idea. On audio systems ground loop protection we want to block low voltage AC, so the version without capacitor is the right one to use (there could be some very small capacitors used on audio isolators for RF protection and sometimes resistors to pass low leakage currents in case installed to system where there is no ground loop).

Elliott Sound Products article Earthing Your Hi-Fi – Tricks and Techniques article give some construction details how A High Current Safety Loop Breaker Circuit (pretty similar to one believed to be inside HumX) could be built:

earth-f4

This circuit example has the ground isolator between the mains power ground and audio part zero voltage line. Here the circuit the current loop breaking the loop is done with the 10 Ohm resistor, the current is now less than 200mA, and the voltage across the interconnect will be very much smaller, reducing the hum to the point where it should no longer be audible. This is how the circuits work when the potential difference over the 10 ohm resistor is lower than the voltage drop of the diodes on the rectifier bridge (around 1.2-1.4V). The capacitor will pass high frequencies (RFI protection).

In case there are is some serious ground leakage the diodes will start to conduct and pass through enough current needed to burn the mains fuse if needed without too much vooltage drop (no dangerous voltages over the isolator circuit). In the event of a major fault, one (or more) of the diodes in the bridge will possibly fail. Semiconductors (nearly) always fail as short circuit, and only become open circuited if the fault current continues and ‘blows’ the interconnecting wires. High current bridge rectifiers have very solid conductors throughout, and open circuit diodes are very rare. Use of the bridge means that there are two diodes in parallel for fault current of either polarity, so the likelihood of failure (to protect) is very small indeed.

If you plan to do any experimenting in this field, make sure that you find out the legal requirements in your country, and don’t do anything that places you at risk – either from electrocution or legal liability. Neither is likely to be a pleasant experience.

Electrical safety cannot be over emphasised. Hum is damn annoying, and everyone wants it gone. There is no good reason to sacrifice one for the other, since safety and hum-free operation can peacefully co-exist with care and the right techniques.

cheaterplug_th

NEVER use a three prong to two prong AC adapter to fix a ground loop problem. These devices are meant to provide a safety ground (via the cover plate screw to a grounded outlet) in the event a three prong plug is used with a two prong outlet in USA. It is wrong and dangerous trying to use such adapter to break the safety ground connection. Also do not try to use any other adapter that breaks the ground connection (some travel adapters).

59 Comments

  1. Car Audio Static only when i turn engine on and revv the motor? | Electronics In Car says:

    [...] Secrets of hum elimination plug « Tomi Engdahl’s ePanorama blog [...]

    Reply
  2. dental hygienist says:

    this post is very usefull thx!

    Reply
  3. Earlene Ziebart says:

    Hai admin , This is good posting for my homework from school Do u have twitter account ?? i want to follow your twitt . bye

    Reply
  4. Jon Brink says:

    Too bad so many people hock their stuff so cheaply. It’s really kind of ruining our hobby.

    Reply
  5. Jon Brink says:

    I wish there were more pictures (I admit it… I’m a photo junkie).

    Reply
  6. Notebook Power Supply says:

    This is a great resource, useful for anybody interested in this topic.

    Reply
  7. Akiko Lu says:

    Thank You for sharing this!

    Reply
  8. Ty Survant says:

    Best internet site, i love it!

    Reply
  9. dentist brooklyn says:

    Its not a whole lot of sites that i visit regularly except for yahoo and cnn, but i think im going to be adding your blog into my daily mix. Such great writing…powerful content. Hope to see a whole lot more from you in the future.

    Reply
  10. dentist in brooklyn says:

    Powerful blog entry. You definitely understand what you are talking about here. Im so glad I was able to locate this website. I hope to see more great posting from you. Keep up the powerful work.

    Reply
  11. Barton Boeding says:

    charging my bb using a $1 usb cord bought off amazon & an ipod charger. almost spent $30 on an authentic! i have a genius friend

    Reply
  12. tomi says:

    I don’t know, but I doubt that.
    I don’t live in Alabama.
    How my blog resolves to Alabama?

    Reply
  13. Johann says:

    What an excellent description! No idea how you were able to say this post..it’d take me days. Well worth it though, I’d suspect. Have you considered selling advertising space on your blog?

    Reply
  14. Rodolfo Wulff says:

    Thanks for every other informative web site. Where else may just I get that kind of information written in such a perfect method? I have a venture that I am simply now operating on, and I have been at the glance out for such info.

    Reply
  15. rear-view camera says:

    Haven’t heard of Hum before, need to check this plug out it looks good!

    Reply
  16. Crystal Hobbes says:

    Good site! I really love how it is easy on my eyes and the data are well written. I am wondering how I might be notified whenever a new post has been made. I’ve subscribed to your feed which must do the trick! Have a nice day! “If you are going to do something wrong at least enjoy it.” by Leo C. Rosten.

    Reply
  17. strivectin neck cream says:

    You must take part in a contest for top-of-the-line blogs on the web. I will recommend this web site!

    Reply
  18. Tim Nevue says:

    I want I want! First off I’m a total cover junkie so I’d want it just for that then its by Vicki Petterson so it’s a gotta have

    Reply
  19. fgaksjdlakwa says:

    This is the punish Secrets of hum elimination plug Tomi Engdahl’s ePanorama blog diary for anyone who wants to essay out out almost this substance. You notice so untold its virtually exhausting to reason with you (not that I rattling would want…HaHa). You definitely put a new twist on a matter thats been typewritten roughly for age. Fastidious congest, just large!

    Reply
  20. Darell Mallari says:

    Many thanks so significantly for exceptional particulars, wonderful evaluation, I’ll revisit your internet website the really next time.

    Reply
  21. Consuela Steans says:

    I have to admit which you’ve got made this kind of valuable website, My spouse and i came across it in Bing.

    Reply
  22. nikotin says:

    Great weblog you got right here, continue the great work, appreciate studying your thoughts as well as would like to follow you for a long period, i never thought I would look for a excellent site like this one, many websites are so poor that you simply simple simply waste your time studying all of them!

    Reply
  23. Georgiann Laba says:

    Hi there! remarkable weblog website! I am a common web site visitor to be able to yours

    Reply
  24. Cherlyn Side says:

    I really like reading methods by intriguing freelance writers. UniFi

    Reply
  25. Jimmy Hollier says:

    What a funny blog! I actually enjoyed watching this humorous video with my family unit as well as together with my friends.

    Reply
  26. Da says:

    Hi, I think I want to try this method in a few of my power supplies. What is the purpose of the 1K impedance? Is it parallel to the diodes? or in series with the diodes (which are in parallel to each other)? Would it need to be a high power resistor? Thanks.

    Reply
    • tomi says:

      The 1Kohm impedance is connected in parallel with the diodes as I understood on the original description (and that makes most sense).
      The purpose is that the resistor tries to keep the diodes from conducting (which is not good for noise perspective) due small leakage current that can exist…
      If the current stays below 0.5 mA (=0.5V voltage drop over resistor), the diode will not conduct. In case of two diodes in series are used it would take 1 mA leakage before diodes start to conduct.
      Normal equipment have typically less than 1 mA leakage current from live to ground.

      In circuit referred on my article (from http://sound.westhost.com/earthing.htm ) there is 10 ohm resistor in parallel with the diodes.
      In this circuit the resistor and capacitor in parallel with the diodes try to keep the diodes from not start to conduct due small leakage currents…

      Reply
  27. Finn Comfort says:

    Simply reading the blog post many will like this because its accurate so its nifty seeing a guy that’s telling topics like this on the net to think about.

    Reply
  28. Safilo Elasta says:

    Regarding going through the above blog post readers will like the above as it’s valid so its good seeing an author thats stating it on the internet to consider!

    Reply
  29. Tomi Engdahl says:

    Intriguing science of galvanic isolators for boats.
    https://www.youtube.com/watch?v=EjQb26juVYo

    You probably don’t NEED to know this, but it’s interesting, and one of those things that one day you may actually benefit from the knowledge, and not necessarily even in relation to anything nautical.
    There’s a surprising amount of electrical science behind the simple concept of a boat floating in the sea. But when they hook up to shore power then things can get really bad if they don’t have a simple device called a galvanic isolator fitted in the ground/earth wire.
    This video explores the science and shows how a simple galvanic isolator is made.

    Reply
  30. J. G. Cardoso says:

    Could someone kindly tell me whether would it be fair to say that the inner impedance of the Ebtech Hum X – Plug-Style AC Voltage Ground Loop Hum Eliminator, is 20 ohms. I should confirm this in order to estimate some relevant current values here. Many thanks.

    Reply
    • Tomi Engdahl says:

      I can’t verify that 20 ohms value.
      It could be at that range or something else.
      To be able to verify that I would need to have such device on my hands (which I don’t have) and do some lab measurements.
      That would sort out the impedance.

      Most propably the impedance is not fixed, it has some value for low level signals (less than 1 V or so), and when signal levels get higher the impedance starts to drop due the diodes on the circuit expected to be inside it starting to conduct.

      Reply
  31. Tomi Engdahl says:

    Ground Loop Hum Eliminator
    https://www.youtube.com/watch?v=CuvDMjxhE68

    Instructional video on eliminating ground loop hum in a multi-amp setup. This DIY project is a hum-loop block network circuit and helps to safely isolate ground, preventing ground hum. It is based on publicly available information. I run five amps at once in a layered configuration and have no ground hum.

    OBLIGATORY LEGAL DISCLAIMER: This project requires knowledge of AC wiring (USA). DO NOT ATTEMPT TO BUILD THIS unless you are experienced with AC wiring and electronics. MIS-WIRING CAN RESULT IN SEVERE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

    Reply
  32. Tomi Engdahl says:

    Understanding Ground Loops
    https://www.youtube.com/watch?v=4YM1iwC6vhg

    David Hosler demystifies the elusive ground loop. If you plug in, watch this video for important—and easy—information that all performers need to know.

    Troubleshoot and Eliminate AC Hum on Sound System
    https://www.youtube.com/watch?v=l4famaQmWnA

    Reply
  33. Tomi Engdahl says:

    How to Stop Unwanted Buzzing or Humming From Disco DJ Sound Systems and PA
    https://www.youtube.com/watch?v=g3WTyV5Lrzo

    Ground loop isolator for eliminating Buzzing or Humming noises when using your sound system or PA rig and a laptop computer. This simple but great device is designed to isolate the ground between source and amplification to prevent noise or hum. This is a very common problem for DJ’s, bands and is a must for anyone using a Laptop in conjunction with their PA Sound System due to earth (Ground) mismatch. Simply connect this small device to the input of your amplifier or mixer, then connect your input from the Laptop or DJ Controller into the other end of this small device and away you go!

    Reply
  34. Tomi Engdahl says:

    Ground Loop Hum Eliminator
    https://www.youtube.com/watch?v=CuvDMjxhE68

    Instructional video on eliminating ground loop hum in a multi-amp setup. This DIY project is a hum-loop block network circuit and helps to safely isolate ground, preventing ground hum. It is based on publicly available information.

    OBLIGATORY LEGAL DISCLAIMER: This project requires knowledge of AC wiring (USA). DO NOT ATTEMPT TO BUILD THIS unless you are experienced with AC wiring and electronics. MIS-WIRING CAN RESULT IN SEVERE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. I make no claim that this device will work in all situations or that it is safe to use.

    Reply
  35. Tomi Engdahl says:

    Grounding and Circuit Protection for Inverters and Battery Chargers
    https://www.bluesea.com/resources/101

    The rules for grounding electrical systems have evolved over time. Boat builders, installers, and electricians continue to recognize hazards and increase safety measures

    It was found that faults in the DC wiring or the DC side of chargers could generate fires because high current could flow back from the batteries, so a fuse was added between inverters or chargers and the battery system.

    Now three critical grounding wires for these systems have been identified. This may seem excessive, but this combination of grounding conductors has been shown to give protection against a wide variety of faults.

    Reply
  36. jon loomer says:

    It would isolate the guitar from the amp and should work, though I have no experience with a guitar. Another solution would be to use an Ebtech HumX for all your U-ground 3-pin power plugs to isolate them and avoid ground loops.

    Reply
  37. Tomi Engdahl says:

    Intriguing science of galvanic isolators for boats.
    https://www.youtube.com/watch?v=EjQb26juVYo

    There’s a surprising amount of electrical science behind the simple concept of a boat floating in the sea. But when they hook up to shore power then things can get really bad if they don’t have a simple device called a galvanic isolator fitted in the ground/earth wire.
    This video explores the science and shows how a simple galvanic isolator is made.

    Reply
  38. Tomi Engdahl says:

    Ground Loop Hum Eliminator
    https://www.youtube.com/watch?v=CuvDMjxhE68

    Instructional video on eliminating ground loop hum in a multi-amp setup. This DIY project is a hum-loop block network circuit and helps to safely isolate ground, preventing ground hum. It is based on publicly available information.

    $2 DIY Hum Suppressor
    https://www.youtube.com/watch?v=qNQX8jyxRrs

    In this video though we build a device that can help reduce the effects of ground loops and subsequent hum. Parts needed can sometimes be salvaged from old electronics for free, or like me purchased online for under $20.

    Parts used:

    Two high-voltage diodes; 6A 500V minimum recommended.
    One 1K Ohm resistor
    Power cable /w ground pin
    Soldering iron and epoxy

    While we do introduce some safety mechanisms, this build is not advised; the potential safety concerns of dealing with household power are significant. It also may be illegal to use in your region.

    You build one at your own peril.

    Reply
  39. Tomi Engdahl says:

    Intriguing science of galvanic isolators for boats.
    https://www.youtube.com/watch?v=EjQb26juVYo

    You probably don’t NEED to know this, but it’s interesting, and one of those things that one day you may actually benefit from the knowledge, and not necessarily even in relation to anything nautical.
    There’s a surprising amount of electrical science behind the simple concept of a boat floating in the sea. But when they hook up to shore power then things can get really bad if they don’t have a simple device called a galvanic isolator fitted in the ground/earth wire.
    This video explores the science and shows how a simple galvanic isolator is made.

    Reply
  40. Tomi Engdahl says:

    Ground Loop Hum Eliminator
    https://www.youtube.com/watch?v=CuvDMjxhE68

    Instructional video on eliminating ground loop hum in a multi-amp setup. This DIY project is a hum-loop block network circuit and helps to safely isolate ground, preventing ground hum. It is based on publicly available information.

    OBLIGATORY LEGAL DISCLAIMER: This project requires knowledge of AC wiring (USA). DO NOT ATTEMPT TO BUILD THIS unless you are experienced with AC wiring and electronics. MIS-WIRING CAN RESULT IN SEVERE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. I make no claim that this device will work in all situations or that it is safe to use.

    Reply
  41. Tomi Engdahl says:

    $2 DIY Hum Suppressor
    https://www.youtube.com/watch?v=qNQX8jyxRrs

    Hum and Buzz is often caused by a Ground Loop in audio equipment. While many solutions exist at removing a ground loop or filtering out the resultant noise, the best solution aren’t always the cheapest. In this video though we build a device that can help reduce the effects of ground loops and subsequent hum. Parts needed can sometimes be salvaged from old electronics for free, or like me purchased online for under $20.

    Two high-voltage diodes; 6A 500V minimum recommended. One 1K Ohm resistor Power cable /w ground pin Soldering iron and epoxy While we do introduce some safety mechanisms, this build is not advised; the potential safety concerns of dealing with household power are significant. It also may be illegal to use in your region.

    Reply
  42. Tomi Engdahl says:

    Ground Loops and Hum
    https://www.youtube.com/watch?v=GS-6jBk9YPM

    How Ground Loops happen and how to avoid them.

    Understanding Ground Loops
    https://www.youtube.com/watch?v=4YM1iwC6vhg

    David Hosler demystifies the elusive ground loop. If you plug in, watch this video for important—and easy—information that all performers need to know.

    Reply
  43. Tomi Engdahl says:

    Circuit Cellar
    Find and Eliminate Ground Loops
    https://bit.ly/2l0vvei

    Figure 4 shows how to break ground for appliances, such as a PC, with three-prong plugs. You can build this circuit into a computer or another appliance, but I find it better to build it as an independent break-out box. The diodes provide open loop for signals up to about 1.3 VPP. A hum is usually of a substantially lower amplitude. C1, 0.01 µF, provides bypass for high-frequency EMI to ground. The loop would be closed for voltages higher than 1.3 VPP, such as the ones due to isolation fault of the hot wire to the chassis. For 120 VAC distribution, D1, D2, and C1 should be rated for 250 V at a minimum. In a circuit branch with a 15-A breaker or fuse, the diodes need to be rated for a minimum of 20 A so that the breaker opens up before the diodes blow.

    Reply
  44. Tomi Engdahl says:

    $2 DIY Hum Suppressor
    https://www.youtube.com/watch?v=qNQX8jyxRrs

    Hum and Buzz is often caused by a Ground Loop in audio equipment. While many solutions exist at removing a ground loop or filtering out the resultant noise, the best solution aren’t always the cheapest.

    In this video though we build a device that can help reduce the effects of ground loops and subsequent hum. Parts needed can sometimes be salvaged from old electronics for free, or like me purchased online for under $20.

    Parts used:

    Two high-voltage diodes; 6A 500V minimum recommended.
    One 1K Ohm resistor
    Power cable /w ground pin
    Soldering iron and epoxy

    While we do introduce some safety mechanisms, this build is not advised; the potential safety concerns of dealing with household power are significant. It also may be illegal to use in your region.

    You build one at your own peril. This video is for entertainment ( and ASMR ) purposes, only.,

    Comments:

    “$2 Suppressor but then burns down your $300,000 house…..HA!”

    “I think that this device won’t meet the electrical code requirements for current carrying capacity for a ground conductor in Canada abd USA. If not and your house burns down your insurance won’t pay if they can prove the fire was caused by this device. Same for if someone is injured oe electrocuted. That may be why the commercual unit is so expensive. It meets Code.”


    Siana Gearz
    3 months ago
    I don’t think the commercial device necessarily meets code, after all it has not been certified by any independent authority. However, what it does, is it shifts responsibility, and builds up their legal fund in case they are sued. If something happens, there’s no way YOU could have known that you have been scammed and possibly sold an illegal device, it’s just not your responsibility any longer.”

    “Practical relevance of whether the device is sane is likely to be minor in States and Canada, i mean realistically, you’re not going to have a GFCI anyway, as opposed to Europe. ”

    “That cable while it was unmodified would have a been certified by UL and been CSA approved. Once you modify something like this, it’s no longer certified and backed by its manufacturer. In Canada, it is illegal to connect any non CSA approved to device to the power grid.
    Bottom line, don’t get caught with a home-brew cable like this, especially in the case of a fire”

    “Ground loops are NOT always the cause of 60 Hz hum”

    “I wanted to mention that too. Most true ground loops cause a caracteristic “Motor Boating” put-put-put or slower thump- thump-thump sound that can be quite loud ! They sound nothing like AC hum. Levels of stray AC in a home are high. On stage or in a production environment they are crazy high. Like several volts over a few inches of wire can be induced. Un-balanced conductors, poor shielding and bad grounds on signal cables are the usual culprits. Bad design and component layouts cause AC hum problems for the life of lots of equipment. Then it’s failing filter capacitors. Changing component values and coupling capacitors that get you in the end. On the AC side I have found there may well be grounds at different potentials…say circuits from several breaker boxes in the same area. This gadget might help??? IDK…Did it help this guy …?.”

    “Most guitar amps and pre amps have ground lifts. Is the circuit the same as this diagram”

    “Unless those diodes are rated at 20 amp each I would not use them. Better to use a cable ferrite”

    “This is not a hum suppressor, it is a grounding safety gadget which may help with hum reduction. Highly recommended to just buy a cheap audio transformer is you are not dealing with high power audio signals.”

    “Thanks for the reply. Great video. I have to admit that even the best isolation transformer will distort the waveform a bit. It will also change unbalanced signal into the differential signal which can be a problem. If you are willing to spend some money to eliminate the humming completely, get a mains isolation transformer, connect all the appliances to the transformer without grounding any of them(cut the ground wires somehow), and manually ground all of them to the mains earth(the GND of the wall outlet, not the midpoint tapping of the isolation transformer). Note that none of the appliances is isolated. You must ground them to mains earth. If they float on the secondary of the isolation transformer, humming will be picked up and nothing will get fixed. This is the setup I am currently using and I get zero humming or current noise. It also helps to filter out noises on the mains.”

    Reply
  45. Tomi Engdahl says:

    Ground Loop Hum Eliminator
    https://www.youtube.com/watch?v=CuvDMjxhE68

    Instructional video on eliminating ground loop hum in a multi-amp setup. This DIY project is a hum-loop block network circuit and helps to safely isolate ground, preventing ground hum. It is based on publicly available information. I run five amps at once in a layered configuration and have no ground hum.

    OBLIGATORY LEGAL DISCLAIMER: This project requires knowledge of AC wiring (USA). DO NOT ATTEMPT TO BUILD THIS unless you are experienced with AC wiring and electronics. MIS-WIRING CAN RESULT IN SEVERE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

    Reply
  46. Tomi Engdahl says:

    Ground Loop Hum Eliminator
    https://www.youtube.com/watch?v=CuvDMjxhE68

    Instructional video on eliminating ground loop hum in a multi-amp setup. This DIY project is a hum-loop block network circuit and helps to safely isolate ground, preventing ground hum. It is based on publicly available information. I run five amps at once in a layered configuration and have no ground hum.

    Comments:

    How is using a “cheater plug” that eliminates the ground pin unsafe??

    The amp chassis is no longer grounded directly because the cheater plug eliminates it. If there is a short circuit inside the amp or a problem with the outlet wiring, YOU become the path to ground for electricity. Don’t do it. 

    Ground Loops and Hum
    https://www.youtube.com/watch?v=GS-6jBk9YPM

    Reply
  47. Tomi Engdahl says:

    $2 DIY Hum Suppressor
    https://www.youtube.com/watch?v=qNQX8jyxRrs

    Hum and Buzz is often caused by a Ground Loop in audio equipment. While many solutions exist at removing a ground loop or filtering out the resultant noise, the best solution aren’t always the cheapest.

    In this video though we build a device that can help reduce the effects of ground loops and subsequent hum. Parts needed can sometimes be salvaged from old electronics for free, or like me purchased online for under $20.

    Parts used:

    Two high-voltage diodes; 6A 500V minimum recommended.
    One 1K Ohm resistor
    Power cable /w ground pin
    Soldering iron and epoxy

    It also may be illegal to use in your region.

    You build one at your own peril.

    Comments:

    Don’t let your insurance company find out about this…

    I think that this device won’t meet the electrical code requirements for current carrying capacity for a ground conductor in Canada abd USA. If not and your house burns down your insurance won’t pay if they can prove the fire was caused by this device. Same for if someone is injured oe electrocuted. That may be why the commercual unit is so expensive. It meets Code.

    I don’t think the commercial device necessarily meets code, after all it has not been certified by any independent authority. However, what it does, is it shifts responsibility, and builds up their legal fund in case they are sued. If something happens, there’s no way YOU could have known that you have been scammed and possibly sold an illegal device, it’s just not your responsibility any longer.

    Reply
  48. Tomi Engdahl says:

    Galvanic Isolator Video July 17
    https://www.youtube.com/watch?v=yBtddMoDsbI

    A Galvanic Isolator protects the metal parts (including the hull) of a boat from corrosion from electrical currents. This isolator just plugs into the mains connecting cable. Couldn’t be easier!

    http://galvanic-isolator.co.uk/

    If your boat is made of metal AND you connect to a shore supply, there is a serious risk of Galvanic Currents, Stray electrical currents, and Earth Leakage causing enormous damage to your vessel. A galvanic isolator can prevent this.
    When dissimilar metals are immersed in water, they act as a battery, and when the circuit is completed, an electrical current will flow. We call these currents “Corrosion Currents”.

    In fact, there are TWO types of corrosion current that are often mistaken for the same thing.

    One is Galvanic Current – that’s the current that is caused by your boat’s hull’s interaction with the metals that are naturally present in the bank side.

    The other is DC Leakage, which occurs when current “leaks” from your boat’s electrical circuits and follows a path to the shore supply earth. In my personal experience, this kind of leakage impacts about 1 in 3 boats. When it happens, it can damage your boat with devastating speed.

    the boats are connected together by the earth of the shore supply. If the zinc anodes on any of the other boats in the marina, or even on the pontoons are corroded away or missing, the anodes on YOUR boat will try to protect the other boats, not to mention the marina’s structures too. So if your anodes don’t seem to last as long as you’d like you may have just found out why.

    A Plug in galvanic isolator that simply connects in-line with your mains connecting cable.