MODEL RX-V800 / HTR-5280
TYPE SYMPTOM/REPAIR
SUBJECT I-PROTECTION, BUT AMPLIFIERS ARE GOOD
SYMPTOM:  UNIT IMMEDIATELY SHUTS OFF DUE TO OVER-CURRENT PROTECTION (I-PROTECT).  ALL AMPLIFIERS CHECK GOOD WITH NO EXCESSIVE LINE CURRENT MEASURED WHEN THE POWER RELAY IS BYPASSED USING A VARIAC.  THE COLLECTOR VOLTAGE AT Q35 MEASURES THE SAME DC VOLTAGE AS THE PRI TERMINAL TO THE MICROPROCESSOR.  (NO VOLTAGE DROP ACROSS R92 AND Q35 IS NOT TURNED ON.)  THE VOLTAGE ON PRI CAN BE BETWEEN 1V AND 4V.

CAUSE:  THE MEMORY BACKUP CAPACITOR (C633) HAS LEAKED ELECTROLYTE ONTO THE FUNCTION CIRCUIT BOARD CAUSING VOLTAGE TO LEAK INTO THE PRI CIRCUIT.  THE LEAKAGE MAY NOT BE VISIBLE ON THE BOARD.

SOLUTION:  ONCE A TRUE OVER-CURRENT PROTECTION IS RULED OUT, REMOVE C633 AND CLEAN THE CIRCUIT BOARD CAREFULLY TO REMOVE ALL ELECTROLYTE RESIDUE.  REPLACE C633 WITH A NEW PART.  CLEAR THE PROTECTION HISTORY USING STEP 9 (PRESET RESERVED) IN THE DIAGNOSTIC MODE ON PAGE 19 OF THE SERVICE MANUAL.


BY:
  JGB


ENTERED:
  03/07/03